Positioning | Enterprise Standard | Enterprise Standard | Enterprise Performance | Enterprise GPU Accelerator | GPU Accelerated Computing | High Performance Computing | High Performance Computing | Enterprise/Mainstream | HPC/HDC | Standard | HPC/GPGPU | HPC/GPGPU | Standard | Warm/Cold Storage | Cluster-in-a-Box | Ultra Dense Storage | Ultra Dense Storage | Ultra Density Hot Storage | HPC |
Form Factor | 1U1N rack mount | 2U1N rack mount | 2U1N rack mount | 2U1N rack mount | 2U1N rack mount | 2U1N rack mount | 2U4N rack-mounted | 2U1N rack mount with slide rail | 2U1N rack mount | 2U1N rack mount with slide rail | 4U1N rack mount | 2U1N rack mount with slide rail | 2U1N rack mount with slide rail | 1U1N rack mount with slide rail | 2U2N rack mount | 4U2N rack mount | 4U JBOD rack mount | 3U rack mount JBOF with slide rail | 2U4N rack mount |
Processor | Dual Socket Intel® Xeon® Processor E5 2600-v3/v4 Family | Dual Socket Intel® Xeon® Processor E5 2600-v3/v4 Family | Dual Socket Intel® Xeon® Processor E5 2600-v3/v4 Family | Dual Socket Intel® Xeon® Processor E5 2600-v3/v4 Family | Dual Socket; Intel® Xeon® Processor E5-2600 v3/v4 Family | Dual Socket; Intel® Xeon® Processor E5-2600 v3/v4 Family | Dual Socket Intel® Xeon® Processor E5 2600-v3/v4 Family | Dual Socket; Intel® Xeon® Processor Scalable Family | Quad Socket; Intel® Xeon® processor Scalable family | Dual Socket; AMD® EPYC™ Processor Family | Dual Socket; Intel® Xeon® processor Scalable family | Single Socket; AMD® EPYCTM Processor Family | Single Socket; AMD® EPYC™ Processor Family | Up to Dual Socket; Intel® Xeon® processor Scalable family | Dual Socket Intel® Xeon® Processor E5-2600 v3/v4 Family | Dual Socket Intel® Xeon® Processor E5 2600-v3/v4 Family | NA | NA | Dual Socket per node; Intel® Xeon® processor Scalable family |
| | | | | | | | | | | | | | Supporting single CPU option | | | | | |
Memory | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | 24x DDR4 DIMM slot | 24x DDR4 DIMM slot | 16x DDR4 DIMM slot | 24x DDR4 DIMM slot | 48x DDR4 DIMM slot | 32x DDR4 DIMM slot | 24x DDR4 DIMM slot | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | 16x DDR4 DIMM slot | NA | NA | 16x DDR4 DIMM slot per node; Up to 64x DDR4 DIMM slot per system |
Chipset | Intel® C612 | Intel® C612 | Intel® C612 | Intel® C612 | Intel® C612 | Intel® C612 | Intel® C612 | Intel® C620 series (C622), supporting 10GbE | Intel® C620 series (C621, C627) | SoC, supporting 128 PCIe Gen3 lanes | Intel Lewisburg C620 Series (C622) | SoC, supporting 128 PCIe Gen3 lanes | SoC, supporting 128 PCIe Gen3 lanes | Intel® C620 series (C622) | Intel® C612 | Intel® C612 | NA | NA | Intel® C620 series (C622) |
Storage Controller | Onboard: Intel® C612: 6x SATA 6Gb/s port; | Onboard: Intel® C612: 6x SATA 6Gb/s port; | Onboard: Intel® C612: 6x SATA 6Gb/s port; | Onboard: Intel® C612: 6x SATA 6Gb/s port; | Intel® C612: 2x SATA 6Gb/s port; SATA RAID 0,1,5,10 | Intel® C612: 2x SATA 6Gb/s port; SATA RAID 0,1,5,10 | Onboard: Intel® C612: 6x SATA 6Gb/s port; | Onboard: 12x SATA3 6Gb/s port | Onboard: 14x SATA3 6Gb/s port | Native support from CPU | Onboard: 8x SATA3 6Gb/s port | Up to 8x SATA3 (6Gbps) port | Native support from CPU: | Onboard: 2x SATADOM + 3x miniSAS HD connector | Onboard: | Onboard: | Onboard: | NA | Onboard per node: |
| SATA RAID 0,1,5,10 | SATA RAID 0,1,5,10 | SATA RAID 0,1,5,10 | SATA RAID 0,1,5,10 | PCH SATA: | PCH SATA: | SATA RAID 0,1,5,10 | Inventec storage mezz card options | | 24x SATA 6.0Gb/s port | Inventec storage mezz card options: | 2x onboard M.2 NVMe | Up to 16x SATA3 6Gb/s | | Intel® C612: 2x SATA 6Gb/s port | Intel® C612: 2x SATA 6Gb/s port | Avago Cobra SAS 3x48 SAS3 (12Gb/s) | | 8x SATA3 6Gb/s port |
| Storage mezz card options: | Storage mezz card options: | Storage mezz card options: | Storage mezz card options: | 10 x SATA 6Gb/s port; Intel® RST RAID 0/1/10/5 (AHCI mode); supporting SATADOM | 10 x SATA 6Gb/s port; Intel® RST RAID 0/1/10/5 (AHCI mode); supporting SATADOM | Inventec Storage mezz card options: | Option1: SAS3-3008-8i (12Gb/s) | | 4x NVMe port | Option1: SAS3-3008-8i (12Gb/s) | Supporting up to 2x U.2 NVMe | Up to optional 16x U.2 NVMe port | Supporting 2x M.2 NVMe or SATA | SATA RAID 0,1,10 | SATA RAID 0,1, 10 | Storage Expander middle plane: | | 2x SATADOM |
| Option1: SAS2-2308-8i (6Gb/s) | Option1: SAS2-2308-8i (6Gb/s) | Option1: SAS2-2308-8i (6Gb/s) | Option1: SAS2-2308-8i (6Gb/s) | ASM1061 SATA: | ASM1061 SATA: | Option1: SAS2-2308-8i (6Gb/s) | Option2: SAS3-3216-16i (12Gb/s) | | 2x SATADOM | Option2: SAS3-3316-16i (12Gb/s) | | Supporting Inventec storage mezz card options via interposer | Inventec storage mezz card options: | Inventec storage mezz card options: | Storage Expander middle plane: | Avago Cobra SAS 3x48 SAS3 (12Gb/s) | | |
| Option2: SAS2-2208-8i (6Gb/s) | Option2: SAS2-2208-8i (6Gb/s) | Option2: SAS2-2208-8i (6Gb/s) | Option2: SAS2-2208-8i (6Gb/s) | 4 x SATA 6Gb/s port; Intel® RST RAID 0,1,5,10 | 4 x SATA 6Gb/s port; Intel® RST RAID 0,1,5,10 | Option2: SAS2-2208-8i (6Gb/s) | Option3: SAS3-3224-24i (12Gb/s) | | 2x optional M.2 SATA or NVMe | | | | Option1: SAS3-3216-16i (12Gb/s) | Option: SAS3-3008-8i (12Gb/s) | LSI Cobra SAS 3x48 SAS3 (12Gb/s) | Support for 12Gb Syncro Shared Storage | | |
| | Option3: SAS3-3216-16i (12Gb/s) | Option3: SAS3-3216-16i (12Gb/s) | Option3: SAS3-3216-16i (12Gb/s) | Inventec storage mezz card options: | Inventec storage mezz card options: | Option3: SAS3-3008-8i (12Gb/s) | Option4: SAS3-3324-24i (12Gb/s, RAID) | | Inventec storage mezz card options: | | | | Option2: SAS3-3316-16i (12Gb/s, RAID) | Support for 12Gb Syncro Shared Storage | Support for 12Gb Syncro Shared Storage | | | |
| | Option4: SAS3-3224-24i (12Gb/s) | Option4: SAS3-3224-24i (12Gb/s) | | Option1: SAS3-3008-8i (12Gb/s) | Option1: SAS3-3008-8i (12Gb/s) | | | | Option1: SAS3-3324-24i (12Gb/s, RAID) | | | | | | | | | |
| | | | | Option2: SAS3-3216-16i (12Gb/s) | Option2: SAS3-3216-16i (12Gb/s) | | | | | | | | | | | | | |
| | | | | Option3: SAS3-3224-24i (12Gb/s) | Option3: SAS3-3224-24i (12Gb/s) | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | |
Network Controller | Onboard: | Onboard: | Onboard: | Onboard: | Onboard: | Onboard: | Onboard: | Onboard: | Onboard: Dual 10G SFP+ | Supporting 10GbE/25GbE standard PCIe card | Onboard: | Supporting 10GbE/25GbE standard PCIe network card | Supporting 10GbE/25GbE standard PCIe card | Supporting 10GbE/25GbE/100GbE Mezz card | Onboard: Dedicated 10/100 management port | Onboard: | NA | 10/100/1000M Mgmt port | Supporting 10GbE/25GbE/100GbE mezz card |
| Dedicated 10/100 management port | Dedicated 10/100 management port | Dedicated 10/100 management port | Dedicated 10/100 management port | Dedicated 10/100/1000 management port | Dedicated 10/100/1000 management port | Dedicated 10/100 management port | Dual 10G SFP+ | Supporting 10GbE/25GbE/100GbE standard PCIe network card | Supporting 10GbE/25GbE Mezz card | Dual 10G SFP+ | Supporting 10GbE/25GbE/100GbE Mezz card | | Supporting Inventec PHY Mezz Card | Inventec network OCP mezz card options: | Intel® I350-AM2 Dual Port 1GbE | | | Supporting Inventec PHY mezz card |
| Network OCP mezz card options: | Network OCP mezz card options: | Network OCP mezz card options: | Network OCP mezz card options: | Inventec network OCP mezz card options: | Inventec network OCP mezz card options: | Network OCP mezz card options: | Supporting 25GE / 50GbE / 100GbE Mezz card | Supporting 10GbE/25GbE Mezz card | Inventec network OCP mezz card options: | Supporting 25GbE OCP 2.0 mezz/100GbE standard PCIe card | Inventec network OCP mezz card options: | | Inventec network OCP mezz card options: | Option1: NIC-I350-1GDC | Dedicated 10/100 management port | | | Inventec network OCP mezz card options: |
| Option1: NIC-I350-1GDC | Option1: NIC-I350-1GDC | Option1: NIC-I350-1GDC | Option1: NIC-I350-1GDC | Option1: NIC-I350-1GDC | Option1: NIC-I350-1GDC | Option1: NIC-I350-1GDC | Inventec network OCP mezz card options: | Inventec network OCP mezz card options: | Option1:NIC-I350-1GDC (Dual port 1Gb RJ-45) | Inventec network OCP mezz card options: | Option1: NIC-I599-10GD (Dual port 10Gb SFP+) | | Option1:NIC-I350-1GDC (Dual port 1Gb RJ-45) | Option2: NIC-I599-10GD | Inventec network OCP mezz card options: | | | Option1: |
| Option2: NIC-I599-10GD | Option2: NIC-I599-10GD | Option2: NIC-I599-10GD | Option2: NIC-I599-10GD | Option2: NIC-I599-10GD | Option2: NIC-I599-10GD | Option2: NIC-I599-10GD | Option1: NIC-I350-1GDC (Dual port 1Gb RJ-45) | Option1: NIC-I350-1GDC (Dual port 1Gb RJ-45) | Option2: NIC-I599-10GD (Dual port 10Gb SFP+) | Option1: NIC-I599-10GD (Dual port 10Gb SFP+) | Option2: NIC-I540-10GDC (Dual port 10Gb RJ-45) | | Option2: NIC-I599-10GD (Dual port 10Gb SFP+) | Option3: NIC-I540-10GDC | Option1: NIC-I350-1GDC | | | NIC-I540-10GDC (Dual port 10Gb RJ-45) |
| Option3: NIC-I540-10GDC | Option3: NIC-I540-10GDC | Option3: NIC-I540-10GDC | Option3: NIC-I540-10GDC | Option3: NIC-I540-10GDC | Option3: NIC-I540-10GDC | | Option2: NIC-I599-10GD (Dual port 10Gb SFP+) | Option2: NIC-I599-10GD (Dual port 10Gb SFP+) | Option3: NIC-I540-10GDC (Dual port 10Gb RJ-45) | Option2: NIC-I540-10GDC (Dual port 10Gb RJ-45) | | | Option3: NIC-I540-10GDC (Dual port 10Gb RJ-45) | | Option2: NIC-I599-10GD | | | Option2: |
| | | | | | | | Option3: NIC-I540-10GDC (Dual port 10Gb RJ-45) | | | | | | | | Option3: NIC-I540-10GDC | | | NIC-I599-10GD (Dual port 10Gb SFP+) |
| | | | | | | | | | | | | | | | | | | |
Expansion Slot | 1x PCIe Gen3 x16 (LP/MD2) | 2x PCIe Gen3 x16 (LP/MD2) | 4x PCIe Gen3 x8 (FHHL) | 1x PCIe Gen3 x8 storage mezz slot | 1x PCIe Gen3 x8 storage mezz slot | 1x PCIe Gen3 x8 storage mezz slot | 1x PCIe Gen3 x8 low profile (LP/MD2) | Option1: 3x PCIE Gen3 x16 (Low Profile) | 1x PCIe Gen3 OCP 2.0 A+B NIC mezz | 2x PCIe Gen 3 x16 slot (FHFL) | 2x PCIe Gen3 x16 (Low Profile) | Front (Option): | Option1: 6x PCIe Gen3 x8 (FHFL) | 1x PCH PHY/OCP 2.0 x16 NIC mezz | 2x PCIe Gen3 x8 (LP/MD2) | 1x PCIe Gen3 x8 OCP mezz slot | NA | NA | Rear per node: |
| 1x PCIe Gen3 x16 (FHHL) | 1x PCIe Gen3 x8 storage mezz slot | 1x PCIe Gen3 x8 storage mezz slot | 2x PCIe Gen3 x8 network OCP mezz slot | 1x PCIe Gen3 x8 network OCP mezz slot | 1x PCIe Gen3 x8 network OCP mezz slot | 1x PCIe Gen3 x8 storage mezz slot | Option2: 4x PCIE Gen3 x8 (FHFL), 2x PCIE Gen3 x8 (Low Profile) | Option1: 4x PCIe Gen3 x8 (FHHL) | 2x PCIe Gen 3 x8 slot (FHFL) | 1x PCIe Gen3 x16 (FHHL) | 1x PCIe Gen3 OCP 2.0 A+B mezz for NIC/IB | Option2: 4x PCIe Gen3 x8 + 1x PCIe Gen3 x16 (FHFL) | Additional expansion options: | 1x PCIe Gen3 x8 storage mezz slot | 2x PCIe Gen3 x8 (LP/MD2) | | | 1x PCIe Gen3 OCP 2.0 A+B NIC/PHY mezz |
| 1x PCIe Gen3 x8 storage mezz slot | 2x PCIe Gen3 x8 network OCP mezz slot | 2x PCIe Gen3 x8 network OCP mezz slot | Standard PCIe slots: | Interposer board slots: | Standard PCIe slots: | 1x PCIe Gen3 x8 network OCP mezz slot | 1x PCIe Gen3 OCP 2.0 A+B NIC mezz | Option2: 2x PCIe Gen3 x16 (FHHL) | 2x PCIe Gen 3 x8 slot (Low Profile) | 1x PCIe Gen3 OCP 2.0 A+B NIC mezz | Rear: | | Option1: 1x Standard PCIe Gen3 x16 (Low Profile) | 1x PCIe Gen3 x8 network OCP mezz slot | 1x PCIe Gen3 x16 (FHHL) | | | 1x PCIe Gen3 x16 (Low Profile) |
| 2x PCIe Gen3 x8 network OCP mezz slot | | | Option1: 2x PCIe Gen3 x16 (FHFL) (Double width for GPGPU) | 4x PCIe Gen3 x16 (for GPU card) | 4x PCIe Gen3 x16 | | 1x Inventec Storage mezz | Onboard: 12x slimline x8 + 3x slimline x4 connector | 1x PCIe Gen3 OCP 2.0 A+B NIC mezz | 1x Inventec Storage mezz | 4x PCIe Gen3 x16 for GPGPU (Double-wide, FHFL) | | Option2: 1x Inventec Storage mezz | | 1x PCIe Gen3 x16 (LP/MD2) | | | |
| | | | Option2: 4x PCIe Gen3 x8 (FHHL) | 1x PCIe Gen3 x8 storage mezz slot | | | | | 1x Inventec Storage mezz | | 1x PCIe Gen3 x16 for NIC/IB (FHHL) | | | | | | | |
| | | | | 1x PCIe Gen3 x8 network OCP mezz slot | | | | | | | | | | | | | | |
External IO | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear server node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per node: | Rear per SIM node: | Per rear PCIe switch module: | Rear per node: |
| 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 2x USB 3.0 port | 1x USB 3.0 port | 1x USB 3.0 port | 2x USB 3.0 port | 4x External SAS port | 1x VGA port | 8x 12Gb/s Mini SAS HD Port (SFF-8644) with SAS Link/Status LED | 8x SFF8644 | 2x USB 3.0 ports |
| 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x Health LED/Button | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA connector | 1x VGA port | 1x COM port | 1x Remote Management LAN port | 1x 100M NIC port (RJ45) | 1x mini VGA output port |
| 1x Serial port | 1x Serial port | 1x Serial port | 1x Serial port | 1x Serial port | 1x Serial port | 1x BMC Reset Button | 1x Serial port | 2x SFP+ port | 1x UID Button/LED | 1x UID Button/LED | 1x Serial port | 1x Serial port | 1x Serial port | 1x Remote Management LAN port | 2x 1G NIC port | 1x Uart Console Debug with RJ-45 port | 1x PWR LED/BTN | 1x Power button with LED |
| 1x UID Button/LED | 1x UID Button/LED | 1x UID Button/LED | 1x UID Button/LED | 1x Power Button/LED | 1x Power Button/LED | 1x VGA port | 1x UID Button/LED | 1x RJ45 management port | 1x RJ45 management port | 1x RJ45 management port | 1x UID Button/LED | 1x UID Button/LED | 1x Power Button/LED | 2x 10G NIC port | 1x Remote Management LAN port | 1x Power LED/Button | Rear Panel: | 1x UID button with LED |
| 1x BMC reset button | 1x BMC reset button | 1x BMC reset button | 1x BMC reset button | 1x UID Button/LED | 1x UID Button/LED | 1x RJ45 dedicated IPMI LAN port | 1x RJ45 management port | 1x Power Button/LED | Optional network ports | 2x SFP+ port | 1x RJ45 management port | 1x RJ45 management port | 1x UID Button/LED | 2x USB 3.0 port | 2x USB 3.0 port | 1x UID LED | 1x 100M NIC port (RJ45) | Front per node: |
| 1x RJ45 management port | 1x RJ45 management port | 1x RJ45 management port | 1x RJ45 management port | 1x RJ45 management port | 1x RJ45 management port | 1x UID LED/Button | 2x SFP+ port | 1x UID Button/LED | Front Per node: | Optional network ports | Optional network ports | Optional network ports | 1x RJ45 management port | 1x Power LED/Button | 1x Power LED/Button | 1x System Failure LED | 1x 1000M Mgmt port (RJ45) | 1x Power button with LED |
| 4x 10G network port | Optional network ports | Optional network ports | Optional network ports | Optional network ports | Optional network ports | Optional network ports | Optional network ports | 1x System Health LED | 1x Power Button/LED | Rear IO module: | | | 1x MicroSD slot | 1x UID LED | 1x UID LED | Front per HDD array tray: | 1x PWR LED/BTN | 1x Fault LED |
| Optional network ports | Front Per node: | Front Per node: | Front Per node: | Front Per node: | Front Per node: | Front Per node: | Front Per node: | 1x BMC Reset Button | 1x UID Button/LED | 1x NIC port | Front Per node: | Front Per node: | Optional network ports | 1x BMC Reset BTN | 1x System Failure LED | HDD Active LED | 1x UID LED/BTN | 1x UID button with LED |
| Front Per node: | 1x Power Button/LED | 1x Power Button/LED | 1x Power Button/LED | 1x Power Button/LED | 1x Power Button/LED | 1x Power Button/Power&System LED | 1x Power Button/LED | Optional network ports, up to 2x SFP28 port | 1x System Health LED | 1x System Health LED | 1x Power Button/LED | 1x Power Button/LED | Front Per node: | 1x System Failure LED | Optional OCP NIC ports | HDD Fault LED | 1x CONSOLE port | |
| 1x Power Button/LED | 1x UID Button/LED | 1x UID Button/LED | 1x UID Button/LED | 1x UID Button/LED | 1x UID Button/LED | 1x ID Button/LED | 1x UID Button/LED | Front Per node: | 1x Reset Button | 1x Reset Button | 1x UID Button/LED | 1x UID Button/LED | 1x Power Button/LED | Optional OCP NIC ports | Front per HDD array tray: | HDD Present LED | | |
| 1x UID Button/LED | 1x System Health LED | 1x System Health LED | 1x System Health LED | 1x System Health LED | 1x System Health LED | | 1x System Health LED | 1x Power Button/LED | 2x USB 2.0 port | 1x UID Button/LED | 1x System Health LED | 1x System Health LED | 1x UID Button/LED | Front per HDD array tray: | HDD Active LED | | | |
| 1x System Health LED | 2x Network Status LED | 2x Network Status LED | 2x Network Status LED | 2x Network Status LED | 2x Network Status LED | | 1x Reset Button | 1x UID Button/LED | | 1x Power Button/LED | 1x Reset Button | 1x Reset Button | 1x System Health LED | 1x Power LED/Button | HDD Fault LED | | | |
| 2x Network Status LED | 2x USB 2.0 port | 2x USB 2.0 port | 2x USB 2.0 port | 2x USB 2.0 port | 2x USB 2.0 port | | 2x USB 2.0 port | 1x System Health LED | | 1x RJ45 management port | 2x USB 2.0 port | 2x USB 2.0 port | 1x Reset Button | 1x UID BTN/LED | HDD Present LED | | | |
| 2x USB 2.0 port | | | | | | | | 2x Network Status LED | | Front server node: | | | 2x USB 2.0 port | | | | | |
| 1x HDD Stauts LED | | | | | | | | 2x USB 2.0 port | | 1x Power Button/LED | | | | | | | | |
| | | | | | | | | | | 1x UID LED | | | | | | | | |
| | | | | | | | | | | 1x System Health LED | | | | | | | | |
| | | | | | | | | | | 2x USB 3.0 port | | | | | | | | |
Disk Drive Bay | 1x SATA DOM | 1x SATA DOM or M.2 port | 1x SATA DOM or M.2 port | 1x SATA DOM or M.2 port | Front primary bays: | Rear OS SSD bays: | Internal port per node: | Front primary bays: | Rear primary bays: | Front primary bays: | Front primary bays: | Front Primary Bay: | Front Primary Bay: | Top bays: | Rear bays per node: | Rear OS SSD bays per node: | Top bays: | Top Bays: | Primary bays: |
| Front Primary Bays: | Front Primary Bays: | Front Primary Bays: | Front Primary Bays: | Option1: 24x 2.5" SAS3-12Gb/s hot-plug drive | 2x 2.5" 7mm SATA-6Gb/s hot-plug solid state drive | 1x SATA DOM port | Option1: 12x 3.5" SAS/SATA (including optional 4x NVMe) hot-plug drive | 4x 2.5" SAS/SATA/NVMe hot-plug drive | Option1: 8x 3.5" SATA + 4x NVMe hot-plug drive | Option1: 8x 2.5" SAS/SATA hot-plug drive | Option1: 8x 2.5" SATA3 6Gb/s hot-plug drive | Option1:12x 3.5" SATA3 6Gb/s hot-plug drive | 12x 3.5" SAS/SATA hot-plug drive (with SAS support from HBA/RAID card) | 2x 2.5" 7mm SATA-6Gb/s hot-plug Solid State Drive for OS | 2x 2.5" 7mm SATA-6Gb/s hot-plug Solid State Drive for OS | 70x 3.5" SAS3-12Gb/s hot-plug drive | 80x NVMe U.2 SSD, hot-plug | 24x 2.5" SAS/SATA/NVMe hot-plug drive |
| Option1: 8x 2.5" SAS2-6Gb/s hot-plug drive | Option1: 12x 3.5" SAS2-6G/s hot-plug drive | Option1: 12x 3.5" SAS3-12Gb/s hot-plug drive; | 12x 3.5" SAS2-6G/s hot-plug drive | Option2: 12x 3.5" SAS3-12Gb/s hot-plug drive | Front primary bays: | Front Primary Bays: | Option2: 24x 2.5" SAS/SATA (including optional 4x NVMe) hot-plug drive | Supporting 2x onboard M.2 SATA drive | Option2: 24x 2.5" SATA (including 4x NVMe)hot-plug drive | Option2: 4x 2.5" SAS/SATA + 4x NVMe hot-plug drive (disabling OCP card support) | Option2: 6x 2.5" SATA3 6Gb/s + 2x NVMe hot-plug drive | Option2: 16x 2.5" SATA3 6Gb/s + 8x NVMe hot-plug drive | Lower Front SSD bays: | 4x external SAS3-12Gb/s HD port | Top bays: | | | |
| Option2: 4x 3.5" SAS2-6Gb/s hot-plug drive | Option2: 12x 3.5" SAS3-12Gb/s hot-plug drive (with optional 2x 2.5" rear bay); | support Max. 4x NVMe drive | | | Option1: 24x 2.5" SAS3-12Gb/s hot-plug drive | Option1: 24 x 2.5" SAS2 6Gbs hot-plug disk drive | Optional 4x U.2 or M.2 NVMe drive | | Optional 2x M.2 NVMe/SATA socket | | Supporting 2x onboard M.2 NVMe drive | Option3: 16x NVMe hot-plug SSD | 2x 2.5" 7mm SATA hot-plug drive | Front Primary Bays: | 70x 3.5" SAS3-12Gb/s hot-plug drive | | | |
| | support Max. 4x NVMe drive | Option2: 24x 2.5" SAS3-12Gb/s hot-plug drive | | | Option2: 12x 3.5" SAS3-12Gb/s hot-plug drive | Option2: 12 x 3.5" SAS2 6Gbs hot-plug disk drive | Rear SSD bays: | | Rear SSD bays: | | | | | Option1: 24x 2.5" SAS3-12Gb/s hot-plug drive | | | | |
| | Option3: 24x 2.5" SAS3-12Gb/s hot-plug drive | | | | | | 2x 2.5" SATA hot-plug drive | | 2x 2.5" SATA hot-plug drive | | | | | | | | | |
System Management | IPMI 2.0 compliant | IPMI 2.0 compliant | IPMI 2.0 compliant | IPMI 2.0 compliant | IPMI 2.0 compliant | IPMI 2.0 compliant | IPMI 2.0 compliant | IPMI 2.0 compliant + KVM with Dedicated LAN | IPMI 2.0 compliant + KVM with Dedicated LAN | IPMI 2.0 compliant + KVM with Dedicated LAN | IPMI 2.0 compliant + KVM with Dedicated LAN | IPMI 2.0 compliant + KVM with Dedicated LAN | IPMI 2.0 compliant + KVM with Dedicated LAN | IPMI 2.0 compliant+ KVM with Dedicated LAN | IPMI 2.0 compliant | IPMI 2.0 compliant | SCSI Enclosure Service (SES ) | ASPEED 1250 | IPMI 2.0 compliant+ KVM with Dedicated LAN |
| | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | |
TPM | Option: 1.2 | Option: 1.2 | Option: 1.2 | Option: 1.2 | 1.2 | 1.2 | Option: 2.0 | Option: 2.0 | NA | Option: 2.0 | Option: 2.0 | Option: 2.0 | Option: 2.0 | Option: 2.0 | Option: 2.0 | 2 | | | Option: 2.0 |
Power Supply | 550W Platinum (1+1 redundancy) | 550W Platinum (1+1 redundancy) | 800W Platinum (1+1 redundancy) | GPU SKU: 1400W Platinum (1+1 redundancy); Non-GPU SKU: 550W Platinum (1+1 redundancy) | 1600W (220V) Platinum (1+1 redundancy) | 800W (220V) Platinum (1+1 redundancy) | 1600W Platinum Power Supply (1+1 redundancy) | Option1:1600W (220V) Platinum (1+1 redundancy) | 1600W Platinum (1+1 redundancy) | Option1: 1600W (220V)Platinum(1+1 redundancy) | Option1: 1600W Platinum (3+1 redundancy) | 1600W Platinum (1+1 redundancy) | 800W Platinum(1+1 redundancy) | 2x 550W Platinum | 1400W Platinum (1+1 redundancy) | Option1: 1400W (220V) Platinum (2+2 redundancy) | Option1: 1400W (220V) Platinum (2+1 redundancy) | 2+2 redundancy | 2200W Platinum (1+1 redundancy) |
| | | | | | | | Option2:800W (110V) Platinum (1+1 redundancy) | | Option2: 800W (110V) Platinum(1+1 redundancy) | Option2: 2000W Platinum (3+1 redundancy) | | | | | Option2: 1000W (110V) Platinum (3+1 redundancy) | Option2: 1000W (110V) Platinum (2+1 redundancy) | Option1: 1400W (220V) Platinum | |
| | | | | | | | | | | | | | | | | | Option2: 1600W (220V) Platinum | |
Fan | Non-hotswap fans | 4x 8038 fan | 4x 8038 fan | 4x 8038 fan | 4x 8038 fan | 4x 8038 fan | 4x 6038 fan | 6x 6038 hot-swap fan (5+1 redundancy) | 5x hot-swap dual rotor fan | 6x 6038 hot-swap fan (5+1 redundancy) | GPGPU zone: 5x 8056 fan | 6x 6056 hot-swap fan (5+1 redundancy) | 6x 6038 hot-swap fan (N+1 redundancy) | 6x 4028 system fan, N+1 redundancy | | | | | 12x 4056 dual rotor fan |
| | | | | | | | | | | Server zone: 8x 4056 fan Support hot-swap; | | | 1x 4028 PSU fan | | | | | N+1 redundancy |
| | | | | | | | | | | N+1 redundancy | | | | | | | | |
Safety Regulation | CB, CCC, BSMI, FCC | CB, CCC, BSMI, FCC, UL, GS, SASO, CE, RCM, VCCI | CB, CCC, BSMI, FCC | CB, CCC, FCC, UL, CE, RCM | CCC, CB, UL | CCC, CB, UL | CCC, CE, FCC, UL | CB, CE | CB, CE | CB, CE | CB, CE | CB, CE | CB, CE | CB, CE | CB, CE, FCC, UL | FCC, CE,CB, UL, cUL | FCC, CE,CB, UL, cUL | | CB, CE |
Controller Module | | | | | | | | | | | | | | NA | NA | NA | Dual SAS Expander IO controller Module (Dual IO controller Reduandant Module ) | Switch:5x Broadcom BCM53333 PCIe Switch module | |
| | | | | | | | | | | | | | | | | | Soc: PMC PM8546A, 96x lane, supporting cascade | |
Storage IO Speed | | | | | | | | | | | | | | SAS3 12 Gb/s | SAS3 12 Gb/s | SAS3 12 Gb/s | SAS3 12 Gb/s | | |
Node Interconnection | | | | | | | | | | | | | | | Option1: Intel® built-in NTB PCIe Gen3 x8 | NA | NA | NA | |
| | | | | | | | | | | | | | | Option2: Single 10Gb | | | | |